Gateway Main Menu (Appliance)
The gateway main menu is used to configure networking and application settings. Additionally, it provides access to the privileged (root) shell and other administrative tasks.
gateway91
The
CA API Gateway
main menu is used to configure networking and application settings. Additionally, it provides access to the privileged (root) shell and other administrative tasks.To access the Gateway main menu:
- Is there network connectivity to the Gateway appliance?
- If NO, proceed with step 2.
- If YES, proceed to step 3.
- At the machine (networking not yet set up):If networking is not yet set up, you must either be physically at the Gateway appliance or have remote serial console access. You can access the console of the hardware appliance in one of two ways:
- Plug in a USB keyboard and monitor.
- Use a serial connection. For details, see Connect Using Serial Management Port.
At the login screen, log in as userssgconfigusing the default password7layer. The main menu appears.WARNING:You are prompted to change the password the first time you log in as thessgconfiguser. The new password must adhere to the rules described under "Password Rules" in Troubleshooting Password Issues.The ssgconfig account is locked after five (5) unsuccessful login attempts(for standard Gateways as shipped from CA Technologies; lockout counters on custom appliances may differ). To reset this account, see "Unlocking the SSGCONFIG Account" in in Troubleshooting Password Issues. - Remotely (networking has been set up):If networking has been set up, you can either log in locally (as described in step 2 above) or remotely connect via SSH to the Gateway as userssgconfig. For example:
- Linux:ssh ssgconfig@<SSG_host>
- Windows:Use PuTTY or a similar utility
SSH is possible only through eth0, not eth1.Note that not all options are available in every system; for example, option6(Manage HSM) is displayed only if a Hardware Security Module (HSM) is present.The following is the Gateway main menu. Note that the top of the menu shows the Gateway version and the underlying operating system (for example, RHEL or CentOS) and version. When downloading patches for upgrading, be sure to download the patches for the correct operating system.
Welcome to the CA API Gateway - x.x.xx running on CentOS release x.x (Final) This user account allows you to configure the appliance What would you like to do? 1) Configure system settings 2) Display CA API Gateway configuration menu 3) Use a privileged shell (root) 4) Change the Master Passphrase 5) Display Remote Management configuration menu 6) Manage HSM 7) Display Enterprise Service Manager configuration menu 8) Display Patch Management menu 9) Display Log Viewing menu R) Reboot the SSG appliance (apply the new configuration) X) Exit (no reboot) Please make a selection: 1
The following table describes each option in the main menu:
Option | Description |
1) Configure system settings | Use this option to view or configure system settings on the Gateway appliance. These settings must be set up before you can configure the Gateway application. For details, see Gateway System Settings. |
2) Display Layer 7 Gateway configuration menu | Use this option to configure the Gateway application before starting it. For details, see Gateway Configuration Menu. |
3) Use a privileged shell (root) | Use this option to open a command shell with root user privileges. You will need this to perform certain administrative tasks in the Gateway. For more information, see Privileged Shell for Root Commands. The default password is 7layer . |
4) Change the Master Passphrase (not for Thales nShield HSM) | Use this option to change the master passphrase that is used to encrypt the Gateway’s database and keystore passwords. If the master passphrase has been changed from the default, you must enter the current passphrase before specifying a new passphrase. The master passphrase must be between 6 and 128 characters in length. You will be prompted to enter the new master passphrase twice. Hint: It is best to create a lengthy, easy-to-remember phrase using common words. Store the phrase in a safe location.The default master passphrase is 7layer .The "Change the Master Passphrase" option does not apply if you have a Thales nShield HSM enabled on the CA API Gateway. To change the master passphrase in this instance, simply disable and then re-enable the nShield HSM. |
5) Display Remote Management configuration menu | Use this option to configure the Gateway node to be managed remotely. This configuration is required only if the node will be managed by the API Gateway - Enterprise Service Manager. Reboot the Gateway (using option R below) to apply any configuration changes.For details, see Configure the Gateway for Remote Access. |
6) Manage HSM | This option is displayed only if an internal Hardware Security Module (HSM) is present. Select this option to create or program into a security world using the Thales nShield Solo HSM. For details, see Manage Gateway Thales nShield HSM Status Menu. |
7) Display Enterprise Service Manager configuration menu | Use this option to configure the API Gateway - Enterprise Service Manager (if installed).For details, see Configure the Enterprise Service Manager. |
8) Display Patch Management menu | Use this option to manage patches on the Gateway appliance. For details, see Understand Gateway Patches. |
9) Display Log Viewing menu | Use this option to view the various logs available in the system. For details, see Viewing Logs for the Gateway . |
R) Reboot the SSG appliance (apply the new configuration) | Use this option to exit the menu and reboot the appliance. Any configuration changes made will take effect when the Gateway appliance restarts. |
X) Exit (no reboot) | Use this option to exit the menu without rebooting. If you have made configuration changes, they take effect after a reboot. |